Table Oximetry Monitor Contec CMS70A

CNT-CMS70A
10 to 20 days PREORDER
+
546,00 net*
Need help?
More ways of contacting us
CUSTOMER SUPPORT

Whether you're looking for answers, would like to solve a problem, or just want to let us know how we did, you'll find many ways to contact us right here. If you'd like to place an order or have questions regarding your stethoscope.eu order, you can contact us:

  • by using the chat app on bottom right corner of our web page, during business hours (9AM GMT+2 – 5PM GMT+2, 5 days a week) we respond immediately
  • by using our facebook page at https://www.facebook.com/Stethoscope.EU
  • by using the contact form below
  • by phone at +302310005015


If we are offline, we will get back to you as soon as possible. We will do our best to serve you as fast as possible.
Business Hours
Monday: 9:00 AM – 5:00 PM
Tuesday: 9:00 AM – 5:00 PM
Wednesday: 9:00 AM – 5:00 PM
Thursday: 9:00 AM – 5:00 PM
Friday: 9:00 AM – 5:00 PM
Saturday: Closed
Sunday: Closed
Give Feedback

Contec CMS70A Tabletop Oximeter Monitor

Technical Specifications

Display Function

TFT screen and LED display

Screen Resolution

320*240

SpO2 Measurement Range

0%~100% (resolution is 1%)

Accuracy

70%~100%: ± 2%, below 70% unspecified

Pulse Rate Measurement Range

30bpm~250bpm (resolution is 1bpm)

Accuracy

± 2 bpm or ± 2% (whichever is greater)

Performance in Low Perfusion

SpO2 and pulse rate can be displayed correctly when the pulse fill ratio is 0.4%. SpO2 error is ± 4%, and pulse rate error is ± 2 bpm or ± 2%.

Resistance to Ambient Light

The deviation between the value measured in artificial light or indoor natural light and that in a dark room is less than ± 1%.

Power Consumption

Approximately 350 mA

Voltage

AC 100~240V, 50/60HZ

Power Supply

Built-in rechargeable Li-Polymer batteries

Battery Life

Once fully charged, the device's continuous working time is no less than 1 hour.

Safety Type

Class II, Type BF

Features

  • Low power consumption
  • SpO2 value display
  • Pulse value display, bar graph view
  • PI (Perfusion Index) display
  • Pulse waveform display
  • Menu operation
  • Screen brightness can be adjusted
  • Display mode can be changed
  • Pulse sound indicator, can be turned on or off
  • Over-limit measurements, with alarm limits for upper/lower range settings and low voltage alarm
  • Battery capacity display
  • Low voltage indicator: Low voltage alert appears before abnormal operation due to low voltage, with alarm function
  • Connects to an external oximeter sensor
  • Data storage function, stored data can be uploaded to a computer
  • Real-time data can be transmitted to computers